Box Beam

Box Beam industrial roofing and siding are commonly used for industrial warehouses and buildings requiring cryogenic/ temperature control. Box Beam is stronger than our 4” Box Rib.

Notes

LOAD TABLE

PANEL BOX BEAM
LIVE LOAD 20 PSF 30 PSF 40 PSF 50 PSF
SPAN ROOF WALL ROOF WALL ROOF WALL ROOF WALL
18
301 lbs/sq
1 10′-9″ 11′-3″ 9′-7″ 9′-10″ 8′-9″ 8′-11″ 8′-2″ 8′-4″
2 14-5 15-2 12-10 13-3 11-3 12-0 10-1 11-2
3 13-4 13-11 11-9 12-2 10-10 11-1 10-1 10-3
20
233 lbs/sq
1 9-11 10-3 8-9 8-11 8-0 8-1 7-5 7-7
2 12-11 13-9 10-9 12-0 9-5 10-11 8-5 10-0
3 12-2 12-8 10-9 11-1 9-10 10-0 9-2 9-4
22
196 lbs/sq
1 9-3 9-6 8-2 8-4 7-6 7-6 6-11 7-0
2 11-6 12-9 9-7 11-2 8-4 9-10 7-6 8-10
3 11-5 11-9 10-0 10-3 9-2 9-4 8-4 8-8
24
161 lbs/sq
1 8-6 8-8 7-6 7-7 6-10 6-11 6-4 6-5
2 10-0 11-8 8-3 9-9 7-2 8-5 6-5 7-7
3 10-5 10-9 9-2 9-4 8-0 8-6 7-2 7-11
032
65 lbs/sq
1 8-0 9-0 6-7 7-5 5-9 6-5 5-1 5-9
2 7-9 9-0 6-4 7-5 5-6 6-5 4-11 5-9
3 8-7 10-1 7-1 8-3 6-2 7-2 5-6 6-5
040
81 lbs/sq
1 9-11 10-4 8-1 9-0 7-1 7-11 6-4 7-1
2 9-6 11-2 7-10 9-2 6-10 7-11 6-1 7-1
3 10-8 12-6 8-9 10-3 7-7 8-10 6-10 7-11

Have questions?